ГЕНЕРАТОР УСТАНОВКА

PROCEDURE

  1. INSTALL GENERATOR ASSEMBLY

    1. Install the generator assembly with the 2 bolts.

      A012HHGC01
      Момент затяжки
      for bolt A
      35 N*m  { 357 kgf*cm, 26 ft.*lbf }
      for bolt B
      54 N*m  { 551 kgf*cm, 40 ft.*lbf }
    2. Connect the wire harness to terminal B and install the nut.

      A012N7S
      Момент затяжки
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    3. Connect the connector and 2 clamps.

    4. Install the terminal cap.

  2. INSTALL V-RIBBED BELT

    Click here Нажмите здесь

  3. INSTALL NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)

    Click here Нажмите здесь

  4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here Нажмите здесь