ДАТЧИК ПОЛОЖЕНИЯ КОЛЕНЧАТОГО ВАЛА ПРОВЕРКА

PROCEDURE

  1. INSPECT CRANK POSITION SENSOR

    1. Measure the resistance according to the value(s) in the table below.

      A012M4BC01
      *a

      Component without harness connected

      (Crank Position Sensor)

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (NE+) - 2 (NE-) Cold 1630 to 2740 Ω
      Hot 2065 to 3225 Ω
      Note:

      In the table above, the terms "Cold" and "Hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).

      If the resistance is not as specified, replace the crank position sensor.